P

PRODUCTS

PODUCTS
#

HOME > PRODUCTS > SOLUTION >

 MACHINERY INDUSTRY
MACHINERY INDUSTRY

XICHI inverter engraving machine application

P

Products and Applications

PODUCTS
#

Machinery industry

MACHINERY INDUSTRY

XICHI inverter engraving machine application

1, engraving machine functional requirements:
1.1 Control mode selection with V / F control, multi-segment V / F curve.
1.2 requires terminal control as a command source, two-wire terminal control: just a Forward command FWD (XF input).
1.3 ※ frequency source is an analog set (computer control panel Output 0 ~ 10VDC), just from the V1 port input frequency command can be.
1.4 Maximum operating speed is generally 24000r/min, conversion inverter operating frequency is 400Hz (2-class high-speed motor), the minimum cutting speed is 2000r/min,
      we use a non-standard 650Hz can satisfy their requirements.
1.5 Acceleration and deceleration time according to the customer's own needs, usually in the 20 ~ 30s, due to running speed is relatively high, so the need to bring the braking unit inverter.
1.6 requires fault signal output signal and fault reset signal (two programmable relay outputs, X1-X7 multifunction terminals can be reset input).
2, engraving machine performance requirements:
2.1 full-speed range, speed fluctuation is small.
2.2 low-speed torque, low-speed cutting can guarantee.
2.3 deceleration time as short as possible.

     Minimum cutting speed can 500r/min less.Division I CFC710 series inverter can do multi-segment VF curve can be well controlled in different high and low speed torque boost, so they can well meet the requirements of high-speed engraving machine.Single From a functional perspective, the Division I CFC610 series inverter also meet their requirements.
Specific debug parameters (for rated frequency 400Hz, Rated voltage 380V, rated speed 24000):


No.

Parameter code

Settings

Function Description

Remark

1

F000

1

Run the command mode for the external terminal startup


2

F001

2

Frequency setting channel terminal voltageV1Analog Input


3

F004

400HZ

Maximum frequency is400HZ


4

F045

400HZ

Limit corresponds to a frequency of400HZ


5

F006

20-30S

Acceleration time

According to the actual needs of the production process to set

6

F007

20-30S

Deceleration time

7

F018

2

Motor series


8

F019

400HZ

Rated motor frequency


9

F020

380V

Rated motor voltage


10

F021

2

Multipoint CustomV / Fcurve


11

F023

300HZ

V / Ffrequency3

According tothe actualsituation can beforF023-F028intoline properlytunethe whole, securitycardstatus in cuttingstatedoes notover-flow.

12

F024

75% -80%

V / Fvoltage point3

13

F025

100HZ

V / Ffrequency2

14

F026

26% -30%

V / Fvoltage point2

15

F027

0HZ

V / Ffrequency1

16

F028

2% -4%

V / Fvoltage point1